Vai al contenuto principale
Log in / Register
Entra con {$a}
Entra con {$a}
Entra con {$a}
Entra con {$a}
Entra con {$a}
Entra con {$a}
Entra con {$a}
Entra con {$a}
Q-SYS VisionSuite Se ...
Training su richiesta
Q-SYS Training
Sei nuovo/a del Training Q-SYS?
Q-SYS Level One (Q-SYS Livello Uno)
English
Spanish
French
German
Chinese(Mainland)
Chinese(HK,MACAU,TAIWAN)
Portuguese
Q-SYS Control 101 (Controllo di Q-SYS 101)
English
Spanish
French
German
Chinese
Avviamenti rapidi Q-SYS
English
Spanish
Training Q-SYS Quantum
Q-SYS Video 101
English
Spanish
French
Portuguese
Venditore Certificato Q-SYS (nuovo)
Q-SYS Reflect Enterprise Manager
English
Spanish
Training Cinema
Training Cinema 101
Q-SYS Level One For Cinema (Q-SYS Livello Uno per Cinema)
Q-SYS Level Two For Cinema - Bridge Course (Q-SYS Livello Due per Cinema - Corso Ponte)
Training Serie MP-M
English
Spanish
Portuguese
French
Training PLD & CXD
QSC Pro Audio Training
Sei nuovo/a del Training Pro Audio QSC?
Line Array attivo Classe L
Mixer digitali TouchMix
English
Spanish
Italian
Diffusori attivi serie K.2
Diffusori attivi serie CP
Line Array attivo KLA
Luoghi di culto
Applicazione TouchMix
Sound Advice (Consigli sul Suono)
Live Training
Q-SYS Architect (Introductory - Introduttivo)
Q-SYS Level One (Q-SYS Livello Uno)
Q-SYS Level Two (Q-SYS Livello Due)
Standard
Formazione superiore
Cinema
Q-SYS Control (Controllo di Q-SYS)
Control & UCI Fundamentals (Fondamenti di Controllo & Interfaccia Utente)
Control 201 (Controllo 201)
Training per Operatore Certificato TouchMix
Contact
Italiano (it)
Deutsch (de)
English (en)
Español - Internacional (es)
Français (fr)
Italiano (it)
Português - Brasil (pt_br)
Русский (ru)
简体中文 (zh_cn)
PRO AUDIO TRAINING - CLICK HERE
Menu
Training su richiesta
Control & UCI Fundamentals (Fondamenti di Controllo & Interfaccia Utente)
Control 201 (Controllo 201)
Interfaccia Utente avanzata
QSC Pro Audio Training
Sei nuovo/a del Training Pro Audio QSC?
Line Array attivo Classe L
Mixer digitali TouchMix
English
Spanish
Italian
Diffusori attivi serie K.2
Diffusori attivi serie CP
Line Array attivo KLA
Luoghi di culto
Applicazione TouchMix
Sound Advice (Consigli sul Suono)
Sei nuovo/a del Training Pro Audio QSC?
Line Array attivo Classe L
Mixer digitali TouchMix
English
Spanish
Italian
Diffusori attivi serie K.2
Diffusori attivi serie CP
Line Array attivo KLA
Luoghi di culto
Applicazione TouchMix
Sound Advice (Consigli sul Suono)
Sei nuovo/a del Training Pro Audio QSC?
Line Array attivo Classe L
Mixer digitali TouchMix
English
Spanish
Italian
Diffusori attivi serie K.2
Diffusori attivi serie CP
Line Array attivo KLA
Luoghi di culto
Applicazione TouchMix
Sound Advice (Consigli sul Suono)
Live Training
Q-SYS Architect (Introductory - Introduttivo)
Q-SYS Level One (Q-SYS Livello Uno)
Q-SYS Level Two (Q-SYS Livello Due)
Standard
Formazione superiore
Cinema
Q-SYS Control (Controllo di Q-SYS)
Control & UCI Fundamentals (Fondamenti di Controllo & Interfaccia Utente)
Control 201 (Controllo 201)
Control & UCI Fundamentals (Fondamenti di Controllo & Interfaccia Utente)
Control 201 (Controllo 201)
Control & UCI Fundamentals (Fondamenti di Controllo & Interfaccia Utente)
Control 201 (Controllo 201)
Control & UCI Fundamentals (Fondamenti di Controllo & Interfaccia Utente)
Control 201 (Controllo 201)
Contact
Italiano (it)
English (en)
Deutsch (de)
Español - Internacional (es)
Français (fr)
Italiano (it)
Português - Brasil (pt_br)
Русский (ru)
简体中文 (zh_cn)
Log in / Register
Entra con {$a}
Entra con {$a}
Entra con {$a}
Entra con {$a}
Entra con {$a}
Entra con {$a}
Entra con {$a}
Entra con {$a}
Set up Seervision in Q-SYS Designer
Q-SYS VisionSuite Seervision Commissioning Level 1 : Set up Seervision in Q-SYS Designer
Collapse all
Expand all
Close Search Results
CERTIFICATION STEPS COMPLETED
Certification Steps Completed
1 ) Introduction
9m 41s
Course Introduction and VisionSuite Overview
3m 24s
Seervision Technology Overview
6m 17s
2 ) Hardware and Software Overview
2m 44s
Hardware and Software Overview
2m 44s
Assessment
3 ) Set up Seervision in Q-SYS Designer
4m 51s
Set up Seervision in Q-SYS Designer
4m 51s
Assessment
4 ) Setting Up Basic Tracking
5m 20s
Setting Up Basic Tracking
5m 20s
Assessment
5 ) Tracking Tips and Tricks
14m 16s
Smoothness and Deadband
12m 20s
Exclusion Zones
1m 56s
Assessment
6 ) Adding a Static-View Camera
7m 49s
Adding a Static-View Camera
7m 49s
Assessment
7 ) Multiple Presenters
5m 1s
Setting Up Multi-Presenters
5m 1s
Assessment
Video Transcript
Video Transcript
Set up Seervision in Q-SYS Designer
4m 51s
00:07
Welcome back.
00:08
In this part of the training,
00:08
we're going to link Seervision and Q-SYS together,
00:11
which means giving Seervision direct control over our Q-SYS cameras
00:15
and using the Seervision plugin inside Q-SYS.
00:18
We're going to start off in Q-SYS Designer.
00:21
For our first example, we're just going to need one camera.
00:24
So I'm going to create a basic Q-SYS design with an NC 12x80 a mediacast router,
00:30
and I'm going to wire that into the USB bridge on my core.
00:33
Now let's return to the, Seervision user interface.
00:36
Take a look at the menu bar at the top of the page.
00:39
You can see there we have a /1 and a /2 after the server's IP address.
00:44
That's because this is a two channel server.
00:46
And those two buttons let you access the two separate instances of the service and software.
00:51
For now, we just want to configure the first instance.
00:54
So let's press slash one.
00:56
Now the first thing we need to do is connect our camera to Seervision so it can receive the stream
01:02
and control the camera That's done in the operations server.
01:06
Click here to access it.
01:08
Now, in the operations server, we have settings for network licensing and our camera connections.
01:14
We're going to focus on the PTU configuration section for now.
01:19
But what does PTU stand for?
01:21
It's actually a penguin transportation unit. not really.
01:28
PTU stands for Pan Tilt Unit and it comes from Seervision's broadcast background,
01:33
where you might be using cameras that have a separate pan tilt unit to the camera itself.
01:39
Now, of course, we're using Q-SYS and nc-series cameras
01:42
and we can select that as the PTU right here.
01:45
Of course, we need to enter the camera's IP address,
01:48
which you can find in Q-SYS Configurator,
01:50
if you're not sure what it is.
01:51
It might be a good idea to set this to a static address in Peripheral manager,
01:55
just in case you're working on a DHCP network and the camera's IP address changes after a reboot.
02:00
Next, we're going to tell Seervision the camera and the lens.
02:03
that’s attached to the PTU. Of course,
02:06
this is the same in a conferencing camera where everything's integrated.
02:09
So choose Q-SYS as the model and Q-SYS NC 1280 or 20 by 60 as the lens.
02:15
Lastly, we can invert the pan and the tilt for ceiling mounted cameras
02:19
and we can add pan and tilt limits if desired.
02:22
When you're ready, just click apply.
02:26
Now, before we leave the operations server,
02:28
we might want to adjust the IP settings.
02:30
The Q-SYS plug in is going to be connecting to the server via its IP address.
02:35
So it might be a good idea to set this to a static address If you're on a DHCP network.
02:41
When you're ready, just click on the arrow in the top left to go back to the main user interface.
02:48
Next, we need to link our camera stream to the
02:50
Seervision server as well as the PTU control that we've just configured.
administration
Riepilogo della conservazione dei dati