Lesson Description
 
            Command Buttons             
            6m 11s             
          Send simple one-way communication strings to third party devices using Command Buttons.
Video Transcript
 
            Command Buttons             
            6m 11s             
          0:08
 Sometimes, third-party control can be as simple as sending a command to a device, and you’re done! 
0:14
 There are a lot of devices that can be controlled externally, such as projectors, video switchers, 
0:20
 lighting controllers, etc. If all you need to do is send a command to that device and you don’t need to
0:25
 collect any return information from it, then you can use the Command Buttons.
0:30
 These are designed to send simple one-way communication strings to a networked device or a serial 
0:35
 connection. In the Command Buttons’ properties, you can decide how many Command Buttons you 
0:39
 you would like. Each button will send one specific string, and you can add up to 64 buttons in the
0:46
 component. You can also specify if you’re sending commands via TCP, UDP, or Serial. TCP and UDP 
0:53
 commands are simply sent out onto the network, but Serial commands are sent to a physical 
0:58
 Serial connection. When you select Serial, you’ll notice that a trapezoidal pin is added to the 
1:03
 component, which can only be wired to another Serial pin. Many Q-SYS devices have an RS-232
1:10
 port, which is represented within Designer as an Inventory component associated with that device.
1:16
 Simply connect this component to your Command Buttons.
1:20
 If you’re wiring to a Serial port, this is one of the few times you should forget the rule that pins on
1:25
 the left of an object are inputs and pins on the right are outputs. Don’t worry that it looks like 
1:31
 Command Buttons are only receiving information, because – in this case – that single connection
1:35
 works in both directions.
1:38
 Inside the Command Buttons’ control panel, you’ll need to configure some information about the 
1:42
 receiving device. In Serial mode, you’ll need to input the Baud Rate, Data Bits, Parity, and Stop Bits.
1:49
 For TCP and UDP commands, you’ll need the device’s IP address and its communication Port. The IP
1:55
 address is something you may have configured yourself, but you should be able to find all the rest
2:00
 of this information in your device’s user manual or documentation.
2:03
 Let’s push our Designer file to the Core.  Now that we’re up and running, let’s look inside the Serial 
2:09
 Port Block.  When you send a message, there are counters in the block that will show you how many 
2:15
 bytes of data is transmitted or received through the Serial Port. This is very useful for 
2:20
 troubleshooting purposes, like the RS-232 cable not being wired correctly.
2:24
 Other than that – there’s not much to do! Type in the command string here, and when you press the 
2:31
 trigger button on the left it will send that command to the end-device. You could also expose the 
2:37
 Control Pins for each of these triggers, allowing something else within Q-SYS to fire the command.
2:42
 Or, like any other control, you could add these triggers to the Named Controls Bin, allowing you to 
2:49
 schedule these triggers to be activated from your Administrator’s Command Scheduler.
2:54
 Once again, Command Buttons offer one-way communication, so you won’t get any sort of feedback
2:59
 from the device indicating that it received the command, or has performed the action. You do have a 
3:04
 Status indicator that will tell you the health of the connection, but this does not report any 
3:08
 information about the device’s activity. However, if you’re using Command Buttons, it’s probably
3:15
 because you don’t need, or care, about any information returning. For instance, if you can see the 
3:20
 lights change, well then you know the lighting controller received your command. 
3:26
 So the final question, but unfortunately the only difficult one, is this: how do you know what to type 
3:32
 as a command? These commands vary wildly by manufacturer, and you may need to do a little bit of 
3:37
 legwork in order to find them. But most manufacturers, if they’re worth their salt, will have a list of 
3:43
 their device’s commands available somewhere – maybe it’s in a user guide, a supplemental guide, or 
3:49
 you may need to e-mail them directly.  
3:51
 Since there are over 9 trillion different manufacturers of third-party devices, we can’t do much to 
3:56
 help you find those commands. However, we do want to point out one common mistake a lot of 
4:02
 people make. A lot of manufacturers require a carriage return at the end of the command to note
4:07
 that the command string is complete. This information might be displayed in different ways 
4:11
 for instance, this manual display it like so: . 
4:17
 As a quick history lesson, “Carriage return” is sort of an archaic term, referring to a time way before
4:24
 computers when we typed with typewriters. The typewriter’s carriage moved to the left by one 
4:30
 character every time you pressed a key, and when it got the end of the page you would press 
4:34
 “carriage return” to bring it back to the right. The idea of “Carriage Return” has been replaced with
4:40
 the “Enter” key on most keyboards, but you’ll still find this terminology associated with the
4:45
 execution of computer commands.
4:48
 The tricky part is that this text:  should not be typed literally. A carriage return is represented in  
4:55
 different ways in different coding languages, so this instruction here is telling you to input a carriage 
5:01
 return, based on whatever language you’re using. Since Q-SYS uses Lua as it scripting language, you 
5:08
 can enter a carriage return by typing “backslash-r.” The backslash character in Lua tells the compiler 
5:15
 that the following character should not be interpreted literally, and is instead a secret code to 
5:20
 perform some other function. R stands for Return. You could also execute a “new line” command, 
5:27
 which some manuals might call for, with the “backslash-n” command. Or you could use “backslash-x”
5:34
 to signify that the following two characters should be interpreted as a hexadecimal value.
5:39
 Hopefully you won’t have to dig too deep into these types of conversions when using Command 
5:44
 Buttons, but knowing that the backslash-r is often required to cap off your command string that's an
5:50
 important one. These same concepts will actually be useful again if you start coding bi-directional
5:55
 communications using either the Lua script or the Block Controller, which we’ll look at in future 
6:00
 videos. Until then, we have an exercise on the Command Buttons in your Control Training worksheet,
6:05
 so take a look at that before moving on to the next video.