Vai al contenuto principale
Log in / Register
Entra con {$a}
Entra con {$a}
Entra con {$a}
Entra con {$a}
Entra con {$a}
Entra con {$a}
Entra con {$a}
Entra con {$a}
Q-SYS VisionSuite Se ...
Training su richiesta
Q-SYS Training
Sei nuovo/a del Training Q-SYS?
Q-SYS Level One (Q-SYS Livello Uno)
English
Spanish
French
German
Chinese(Mainland)
Chinese(HK,MACAU,TAIWAN)
Portuguese
Q-SYS Control 101 (Controllo di Q-SYS 101)
English
Spanish
French
German
Chinese
Avviamenti rapidi Q-SYS
English
Spanish
Training Q-SYS Quantum
Q-SYS Video 101
English
Spanish
French
Portuguese
Venditore Certificato Q-SYS (nuovo)
Q-SYS Reflect Enterprise Manager
English
Spanish
Training Cinema
Training Cinema 101
Q-SYS Level One For Cinema (Q-SYS Livello Uno per Cinema)
Q-SYS Level Two For Cinema - Bridge Course (Q-SYS Livello Due per Cinema - Corso Ponte)
Training Serie MP-M
English
Spanish
Portuguese
French
Training PLD & CXD
QSC Pro Audio Training
Sei nuovo/a del Training Pro Audio QSC?
Line Array attivo Classe L
Mixer digitali TouchMix
English
Spanish
Italian
Diffusori attivi serie K.2
Diffusori attivi serie CP
Line Array attivo KLA
Luoghi di culto
Applicazione TouchMix
Sound Advice (Consigli sul Suono)
Live Training
Q-SYS Architect (Introductory - Introduttivo)
Q-SYS Level One (Q-SYS Livello Uno)
Q-SYS Level Two (Q-SYS Livello Due)
Standard
Formazione superiore
Cinema
Q-SYS Control (Controllo di Q-SYS)
Control & UCI Fundamentals (Fondamenti di Controllo & Interfaccia Utente)
Control 201 (Controllo 201)
Training per Operatore Certificato TouchMix
Contact
Italiano (it)
Deutsch (de)
English (en)
Español - Internacional (es)
Français (fr)
Italiano (it)
Português - Brasil (pt_br)
Русский (ru)
简体中文 (zh_cn)
PRO AUDIO TRAINING - CLICK HERE
Menu
Training su richiesta
Control & UCI Fundamentals (Fondamenti di Controllo & Interfaccia Utente)
Control 201 (Controllo 201)
Interfaccia Utente avanzata
QSC Pro Audio Training
Sei nuovo/a del Training Pro Audio QSC?
Line Array attivo Classe L
Mixer digitali TouchMix
English
Spanish
Italian
Diffusori attivi serie K.2
Diffusori attivi serie CP
Line Array attivo KLA
Luoghi di culto
Applicazione TouchMix
Sound Advice (Consigli sul Suono)
Sei nuovo/a del Training Pro Audio QSC?
Line Array attivo Classe L
Mixer digitali TouchMix
English
Spanish
Italian
Diffusori attivi serie K.2
Diffusori attivi serie CP
Line Array attivo KLA
Luoghi di culto
Applicazione TouchMix
Sound Advice (Consigli sul Suono)
Sei nuovo/a del Training Pro Audio QSC?
Line Array attivo Classe L
Mixer digitali TouchMix
English
Spanish
Italian
Diffusori attivi serie K.2
Diffusori attivi serie CP
Line Array attivo KLA
Luoghi di culto
Applicazione TouchMix
Sound Advice (Consigli sul Suono)
Live Training
Q-SYS Architect (Introductory - Introduttivo)
Q-SYS Level One (Q-SYS Livello Uno)
Q-SYS Level Two (Q-SYS Livello Due)
Standard
Formazione superiore
Cinema
Q-SYS Control (Controllo di Q-SYS)
Control & UCI Fundamentals (Fondamenti di Controllo & Interfaccia Utente)
Control 201 (Controllo 201)
Control & UCI Fundamentals (Fondamenti di Controllo & Interfaccia Utente)
Control 201 (Controllo 201)
Control & UCI Fundamentals (Fondamenti di Controllo & Interfaccia Utente)
Control 201 (Controllo 201)
Control & UCI Fundamentals (Fondamenti di Controllo & Interfaccia Utente)
Control 201 (Controllo 201)
Contact
Italiano (it)
English (en)
Deutsch (de)
Español - Internacional (es)
Français (fr)
Italiano (it)
Português - Brasil (pt_br)
Русский (ru)
简体中文 (zh_cn)
Log in / Register
Entra con {$a}
Entra con {$a}
Entra con {$a}
Entra con {$a}
Entra con {$a}
Entra con {$a}
Entra con {$a}
Entra con {$a}
Hardware and Software Overview FRENCH
Q-SYS VisionSuite Seervision Commissioning Level 1 (FRENCH) : Aperçu du matériel et des logiciels
Collapse all
Expand all
Close Search Results
CERTIFICATION STEPS COMPLETED
Certification Steps Completed
1 ) Introduction
12m 42s
Video 1 FRENCH
6m 25s
Seervision Technology Overview FRENCH
6m 17s
2 ) Aperçu du matériel et des logiciels
2m 44s
Hardware and Software Overview FRENCH
2m 44s
Assessment
3 ) Configuration de Seervision dans Q-SYS Designer
4m 51s
Connecting Seervision to Q SYS FRENCH
4m 51s
Assessment
4 ) Configuration du suivi de base
5m 20s
Setting Up Basic Tracking FRENCH
5m 20s
Assessment
5 ) Astuces et conseils de suivi
9m 15s
Smoothness and Deadband FRENCH
7m 20s
Exclusion Zones FRENCH
1m 55s
Assessment
6 ) Ajout d'une caméra à vue statique
7m 47s
Adding a Static View Camera FRENCH
7m 47s
Assessment
7 ) Présentateurs multiples
5m 1s
Multi Presenter and Sign Off FRENCH
5m 1s
Assessment
Transcription Vidéo
Transcription Vidéo
Hardware and Software Overview FRENCH
2m 44s
00:08
Il est temps de parler du matériel sevision. Je suis
00:11
donc ici dans la salle de formation et bien sûr, j'ai
00:14
un serveur sevision juste ici.
00:16
L'une des premières choses à savoir sur ces
00:18
serveurs est qu'ils existent en version à canal unique ou double.
00:22
Cela fait simplement référence au nombre de flux
00:24
de caméras qu'ils peuvent traiter simultanément.
00:27
Quel que soit le modèle que vous choisissez, vous
00:30
disposez d'un JPU très puissant à l'intérieur qui traite
00:32
ses flux et effectue la vision par ordinateur.
00:35
En ce qui concerne le boîtier lui même, nous
00:37
avons un panneau avant avec le logo SIEVOGEN
00:40
et le bouton d'alimentation, et à l'arrière, nous avons
00:42
pas mal de connexion, certaines liées à la carte mère et au.
00:46
Mais tout ce dont nous devons vraiment nous préoccuper,
00:48
c'est la connexion de données pour l'ingestion des flux
00:50
de caméra Q 6 et le travail avec Q 6 contrôle et bien sûr
00:54
la connexion d'alimentation pour l'alimenter.
00:58
Maintenant, une fois que votre serveur est connecté
01:00
au réseau et alimenté, nous pouvons voir comment le
01:02
découvrir et comment nous connecter à l'interface web.
01:05
Si vision utilise une interface utilisateur basée sur le web,
01:08
donc pour y accéder, il suffit de saisir l'adresse IP du
01:11
serveur dans Google chrome.
01:13
Par défaut, le serveur utilise une adresse
01:15
IP automatique, donc il aura une adresse DHCP si vous
01:18
avez un serveur DHCP, et ce sera une adresse locale dans
01:21
la page 100609210054 si aucun serveur DHCP n'est présent.
01:26
Dans tous les cas, nous pouvons utiliser l'outil de
01:28
découverte Sevision pour trouver tous les serveurs sur
01:30
notre réseau local. Il suffit de cliquer sur trouver les
01:34
serveurs sevision et une fois que vous avez
01:36
l'adresse, tapez là dans Google chrome.
01:38
Maintenant, nous sommes connectés au serveur et
01:40
nous pouvons voir l'interface utilisateur sevision.
01:43
C'est ici que nous allons lier le serveur à nos caméras,
01:45
créer des zones de suivi et de déclenchement et
01:48
créer différents types de prise de vue et de position
01:50
de caméra. Vous pouvez voir que cela est divisé en 3 sections.
01:54
Au centre, nous avons l'aperçu de la caméra et les
01:56
commandes manuelles PTZ de la caméra.
01:58
À gauche, nous avons un panneau de configuration.
02:01
C'est ici que nous pouvons contrôler notre comportement
02:03
de suivi, créer et éditer diverses zones et activer
02:06
ou désactiver les superpositions sur le flux de la caméra,
02:09
par exemple cette superposition de vision par ordinateur.
02:12
Cela nous montre chaque personne détectée dans
02:14
la scène, leur numéro d'identification unique et les
02:16
points de leur corps qui sont suivis. Enfin, sur le côté droit,
02:19
nous avons le panneau de pré réglage où nous pouvons créer des conteneurs.
02:23
Les conteneurs de prise de vue et de position sont ce
02:25
que le PLUGIN Q 6 rappellera pour démarrer et arrêter le suivi.
02:29
Mais avant de plonger dans tout cela, nous devons
02:31
lire civision et Q 6 ensemble. Ce que nous aborderons
02:35
dans la prochaine vidéo, à bientôt.
administration
Riepilogo della conservazione dei dati